{"product_id":"wiwynn-ava-m-quad-slots-m-2-nvme-ssd-pcie-3-0-x16-carrier-card-supports-2280-22110mm-x4-b48-01201-0011-16335-1","title":"Wiwynn AVA-M Quad Slots M.2 NVMe SSD PCIe 3.0 x16 Carrier Card (Supports 2280\/22110mm (x4)) B48.01201.0011 16335-1","description":"\u003cp\u003e\u003c!--StartFragment--\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\n\u003cstyle type=\"text\/css\"\u003ea {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003c\/p\u003e\n\n\u003ch2 style=\"text-align: justify;\"\u003eWiwynn AVA-M Quad Slots M.2 NVMe SSD PCIe 3.0 x16 Carrier Card\u003c\/h2\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eB48.01201.0011 | PCB 16335-1 | Supports 4x M.2 NVMe SSDs (2280\/22110)\u003c\/h3\u003e\n\n\u003cp style=\"text-align: justify;\"\u003eThe Wiwynn AVA-M Quad M.2 NVMe Carrier Card is a high-performance enterprise-grade PCIe storage expansion adapter designed for hyperscale cloud, data center, workstation, and server environments. This Full-Height Half-Length (FHHL) carrier card supports up to four M.2 NVMe SSDs simultaneously and connects directly through a PCIe 3.0 x16 interface, providing dedicated PCIe 3.0 x4 bandwidth to each installed drive for maximum storage performance.\u003c\/p\u003e\n\n\u003cp style=\"text-align: justify;\"\u003eOriginally developed by Wiwynn, a leading Open Compute Project (OCP) manufacturing partner, the AVA-M carrier card is commonly deployed in hyperscale cloud infrastructures, enterprise servers, and high-performance workstation environments where high-density NVMe storage and efficient scalability are required.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch3 style=\"text-align: justify;\"\u003eProduct Highlights\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eManufacturer: Wiwynn Corporation\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eModel: AVA-M Quad M.2 NVMe Carrier Card\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePart Number: B48.01201.0011\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePCB Number: 16335-1\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePCIe 3.0 x16 Host Interface\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSupports Up to 4 M.2 NVMe SSDs\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eCompatible with M.2 2280 and 22110 Form Factors\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eM-Key NVMe Design\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePassive PCIe Carrier Architecture\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eFHHL (Full Height Half Length) Form Factor\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eEnterprise Data Center Design\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eIntegrated Thermal Armor and Heatsink Assembly\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eActivity and Fault Status LEDs\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eBMC Telemetry Support\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eStorage Configuration\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDrive Capacity: Up to 4 x M.2 NVMe SSDs\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSupported Form Factors:\n\t\u003cul\u003e\n\t\t\u003cli\u003eM.2 2280 (22mm x 80mm)\u003c\/li\u003e\n\t\t\u003cli\u003eM.2 22110 (22mm x 110mm)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eKey Type: M-Key\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eInterface: PCIe NVMe\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSATA M.2 Support: Not Supported\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePer Drive Connection: PCIe 3.0 x4 Dedicated Lanes\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eMaximum Lane Allocation: 16 PCIe Lanes Total\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eHost Interface\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eInterface Type: PCI Express 3.0 x16\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePhysical Slot Requirement: PCIe x16\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eCard Type: Passive PCIe Carrier Card\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eNo onboard PCIe switch (PLX \/ Broadcom \/ PEX)\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDirect lane routing from motherboard to SSD slots\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003ePhysical Characteristics\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eForm Factor: Full Height Half Length (FHHL)\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eCooling Design: Passive\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eThermal Solution:\n\t\u003cul\u003e\n\t\t\u003cli\u003eMetal cover \/ thermal armor\u003c\/li\u003e\n\t\t\u003cli\u003eIndividual heatsink protection over SSD modules\u003c\/li\u003e\n\t\t\u003cli\u003ePre-installed thermal pads\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eAirflow Requirement:\n\t\u003cul\u003e\n\t\t\u003cli\u003eServer-class airflow recommended\u003c\/li\u003e\n\t\t\u003cli\u003eHigh-airflow workstation chassis supported\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eManagement Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eIntegrated BMC Telemetry Support\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDrive Activity LEDs\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDrive Fault LEDs\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eEnterprise Asset Monitoring Support\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eRoHS Environmental Compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eServer Serviceability\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eEnterprise Green Pull-Tab Retention Mechanism\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eToolless Service Design\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDesigned for rack and sled-based deployments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eImportant Compatibility Requirements\u003c\/h2\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003ePCIe Bifurcation Required\u003c\/h3\u003e\n\n\u003cp style=\"text-align: justify;\"\u003eThis carrier card is a passive adapter and requires motherboard support for PCIe lane bifurcation.\u003c\/p\u003e\n\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eRequired BIOS Setting:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePCIe Bifurcation: x4\/x4\/x4\/x4\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eExpected Behavior\u003c\/h3\u003e\n\n\u003ch4 style=\"text-align: justify;\"\u003eIf x4\/x4\/x4\/x4 Bifurcation is Enabled\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eAll four NVMe SSDs are detected\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eFull performance available on all drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4 style=\"text-align: justify;\"\u003eIf x8\/x8 Bifurcation is Used\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eTypically only two SSDs are detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4 style=\"text-align: justify;\"\u003eIf Bifurcation Support Is Unavailable\u003c\/h4\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eOnly one SSD may be detected\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eRemaining drives will not be visible to the operating system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eEnterprise Server Compatibility\u003c\/h2\u003e\n\n\u003cp style=\"text-align: justify;\"\u003eCommonly compatible with systems supporting PCIe x16 bifurcation, including:\u003c\/p\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eDell PowerEdge\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR640\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR650\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR660\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR740\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR740xd\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR750\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eR760\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eHPE ProLiant\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDL360 Gen10\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDL380 Gen10\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDL360 Gen11\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDL380 Gen11\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eSupermicro\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSYS-6019 Series\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSYS-1029 Series\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSYS-620 Series\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eAMD EPYC Platforms\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eAS-1114S-WN10RT\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eWiwynn \/ OCP Platforms\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSV300 Series\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSV5100\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSV7000\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eTioga Pass\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eYosemite\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eLeopard\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eOpen Compute Project Deployments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eWorkstation Compatibility\u003c\/h2\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eDell Precision\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003e5820 Tower\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003e7820 Tower\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003e7920 Tower\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eLenovo ThinkStation\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eP620\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eP920\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eP7\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eP5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eHP Z Workstations\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eZ4 G4\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eZ6 G4\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eZ8 G5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eConsumer Desktop Compatibility\u003c\/h2\u003e\n\n\u003cp style=\"text-align: justify;\"\u003eMay be compatible with enthusiast motherboards that support PCIe bifurcation:\u003c\/p\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eAMD Platforms\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eX570\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eB550\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eX670\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eB650\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: justify;\"\u003eIntel Platforms\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eZ690\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eZ790\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Verify that your motherboard BIOS supports PCIe bifurcation (x4\/x4\/x4\/x4) before purchase.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2 style=\"text-align: justify;\"\u003eIdeal Applications\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eEnterprise NVMe Storage Expansion\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eHigh-Speed SSD Arrays\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eVirtualization Hosts\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eDatabase Servers\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eHyper-Converged Infrastructure\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eSoftware-Defined Storage\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eContent Creation Workstations\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eHomelab Storage Projects\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eOpen Compute Project Deployments\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eCloud Infrastructure Platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr\u003e\n\u003ch3 style=\"text-align: justify;\"\u003ePackage Contents\u003c\/h3\u003e\n\n\u003cul\u003e\n\t\u003cli style=\"text-align: justify;\"\u003eWiwynn AVA-M Quad M.2 NVMe PCIe Carrier Card\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePart Number: B48.01201.0011\u003c\/li\u003e\n\t\u003cli style=\"text-align: justify;\"\u003ePCB Number: 16335-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e SSDs are not included. PCIe bifurcation support is required for all four NVMe slots to function simultaneously.\u003c\/p\u003e\n","brand":"Wiwynn","offers":[{"title":"Default Title","offer_id":55969839480905,"sku":"16335-1","price":94.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/3868\/3209\/files\/0613bda5-fb8f-5100-a817-e8e3c3758cdc.png?v=1787939850","url":"https:\/\/parts.theserverstore.com\/products\/wiwynn-ava-m-quad-slots-m-2-nvme-ssd-pcie-3-0-x16-carrier-card-supports-2280-22110mm-x4-b48-01201-0011-16335-1","provider":"The Server Store Parts","version":"1.0","type":"link"}