{"product_id":"sk-hynix-3-84tb-nvme-u-3-pcie-gen-4-0-x4-ri-sff-2-5-15mm-ssd-pe8110-series-for-lenovo-thinksystem-server-with-tray","title":"SK Hynix 3.84TB NVMe U.3 PCIe Gen 4.0 x4 RI SFF 2.5\" 15mm SSD PE8110 Series for Lenovo ThinkSystem Server with Tray","description":"\u003ch3 data-end=\"123\" data-section-id=\"13ymq6x\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"123\" data-start=\"4\"\u003eSK Hynix 3.84TB NVMe U.3 PCIe Gen 4.0 x4 RI SFF 2.5\" 15mm SSD PE8110 Series for Lenovo ThinkSystem Server with Tray\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"622\" data-start=\"125\" style=\"text-align: justify;\"\u003eThe SK Hynix PE8110 Series 3.84TB NVMe SSD is an enterprise-grade, read-intensive (RI) solid-state drive designed for high-performance data center and enterprise server environments. Featuring a PCIe Gen4 x4 interface with NVMe 1.4 and a U.3 (tri-mode) connector, it delivers exceptional throughput, low latency, and strong reliability for virtualization, cloud computing, and read-heavy workloads. This drive is configured for use in Lenovo ThinkSystem servers with the proper 2.5\" SFF NVMe tray.\u003c\/p\u003e\n\n\u003chr data-end=\"627\" data-start=\"624\"\u003e\n\u003ch3 data-end=\"663\" data-section-id=\"c6jfm2\" data-start=\"629\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"663\" data-start=\"633\"\u003eOther Related Part Numbers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"689\" data-start=\"664\" style=\"text-align: justify;\"\u003eHFS3T8GEETX070N, PE8110\u003c\/p\u003e\n\n\u003chr data-end=\"694\" data-start=\"691\"\u003e\n\u003ch3 data-end=\"728\" data-section-id=\"gqkziz\" data-start=\"696\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"728\" data-start=\"700\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1007\" data-start=\"730\"\u003e\n\t\u003cli data-end=\"754\" data-section-id=\"1apft0h\" data-start=\"730\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"745\" data-start=\"732\"\u003eCapacity:\u003c\/strong\u003e 3.84TB\u003c\/li\u003e\n\t\u003cli data-end=\"777\" data-section-id=\"kbd10\" data-start=\"755\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"768\" data-start=\"757\"\u003eSeries:\u003c\/strong\u003e PE8110\u003c\/li\u003e\n\t\u003cli data-end=\"821\" data-section-id=\"hqykxh\" data-start=\"778\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"794\" data-start=\"780\"\u003eInterface:\u003c\/strong\u003e PCIe Gen4.0 x4, NVMe 1.4\u003c\/li\u003e\n\t\u003cli data-end=\"858\" data-section-id=\"1h9xqms\" data-start=\"822\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"840\" data-start=\"824\"\u003eForm Factor:\u003c\/strong\u003e 2.5\" SFF (15mm)\u003c\/li\u003e\n\t\u003cli data-end=\"912\" data-section-id=\"1n8ex1a\" data-start=\"859\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"875\" data-start=\"861\"\u003eConnector:\u003c\/strong\u003e U.3 (backward compatible with U.2)\u003c\/li\u003e\n\t\u003cli data-end=\"954\" data-section-id=\"142nq4b\" data-start=\"913\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"930\" data-start=\"915\"\u003eNAND Flash:\u003c\/strong\u003e 128-layer 3D TLC NAND\u003c\/li\u003e\n\t\u003cli data-end=\"1007\" data-section-id=\"6hn1rx\" data-start=\"955\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"975\" data-start=\"957\"\u003eWorkload Type:\u003c\/strong\u003e Read Intensive (RI) (~1 DWPD)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1012\" data-start=\"1009\"\u003e\n\u003ch3 data-end=\"1033\" data-section-id=\"1lfaz9a\" data-start=\"1014\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1033\" data-start=\"1018\"\u003ePerformance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1227\" data-start=\"1035\"\u003e\n\t\u003cli data-end=\"1077\" data-section-id=\"dhvoj6\" data-start=\"1035\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1057\" data-start=\"1037\"\u003eSequential Read:\u003c\/strong\u003e Up to ~6,200 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"1121\" data-section-id=\"1p24x5e\" data-start=\"1078\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1101\" data-start=\"1080\"\u003eSequential Write:\u003c\/strong\u003e Up to ~3,800 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"1170\" data-section-id=\"v09ly2\" data-start=\"1122\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1145\" data-start=\"1124\"\u003eRandom Read (4K):\u003c\/strong\u003e Up to ~1,000,000+ IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1227\" data-section-id=\"j474sx\" data-start=\"1171\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1195\" data-start=\"1173\"\u003eRandom Write (4K):\u003c\/strong\u003e Up to ~150,000 – 180,000 IOPS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1232\" data-start=\"1229\"\u003e\n\u003ch3 data-end=\"1264\" data-section-id=\"mdt5dj\" data-start=\"1234\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1264\" data-start=\"1238\"\u003eReliability \u0026amp; Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1458\" data-start=\"1266\"\u003e\n\t\u003cli data-end=\"1292\" data-section-id=\"n1c8u3\" data-start=\"1266\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1282\" data-start=\"1268\"\u003eEndurance:\u003c\/strong\u003e ~1 DWPD\u003c\/li\u003e\n\t\u003cli data-end=\"1331\" data-section-id=\"1t67461\" data-start=\"1293\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1304\" data-start=\"1295\"\u003eMTBF:\u003c\/strong\u003e Up to ~2.5 million hours\u003c\/li\u003e\n\t\u003cli data-end=\"1383\" data-section-id=\"15oisd4\" data-start=\"1332\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1349\" data-start=\"1334\"\u003eEncryption:\u003c\/strong\u003e AES 256-bit hardware encryption\u003c\/li\u003e\n\t\u003cli data-end=\"1418\" data-section-id=\"1ygajnm\" data-start=\"1384\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1412\" data-start=\"1386\"\u003ePower Loss Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\t\u003cli data-end=\"1458\" data-section-id=\"1gtkxx1\" data-start=\"1419\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1452\" data-start=\"1421\"\u003eEnd-to-End Data Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1463\" data-start=\"1460\"\u003e\n\u003ch3 data-end=\"1505\" data-section-id=\"1wrnuto\" data-start=\"1465\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1505\" data-start=\"1469\"\u003eLenovo ThinkSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1645\" data-start=\"1507\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1562\" data-start=\"1507\"\u003eThinkSystem V3 (PCIe Gen4\/Gen5 – Full Performance):\u003c\/strong\u003e\u003cbr data-end=\"1565\" data-start=\"1562\"\u003e\nSR630 V3, SR650 V3, SR655 V3, SR665 V3, SR850 V3, SR860 V3, SR950 V3, ST650 V3\u003c\/p\u003e\n\n\u003cp data-end=\"1774\" data-start=\"1647\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1697\" data-start=\"1647\"\u003eThinkSystem V2 (PCIe Gen4 – Full Performance):\u003c\/strong\u003e\u003cbr data-end=\"1700\" data-start=\"1697\"\u003e\nSR630 V2, SR650 V2, SR645, SR665, SR850 V2, SR860 V2, ST650 V2, SN550 V2\u003c\/p\u003e\n\n\u003cp data-end=\"1904\" data-start=\"1776\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1831\" data-start=\"1776\"\u003eThinkSystem Gen1 (PCIe Gen3 – Performance Limited):\u003c\/strong\u003e\u003cbr data-end=\"1834\" data-start=\"1831\"\u003e\nSR630, SR650, SR530, SR550, SR570, SR590, SR850, SR860, SR950, ST550\u003c\/p\u003e\n\n\u003chr data-end=\"1909\" data-start=\"1906\"\u003e\n\u003ch3 data-end=\"1956\" data-section-id=\"nx6pfh\" data-start=\"1911\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1956\" data-start=\"1915\"\u003eIncluded Tray \/ Hardware Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2092\" data-start=\"1958\"\u003e\n\t\u003cli data-end=\"2000\" data-section-id=\"1f5d5c6\" data-start=\"1958\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1998\" data-start=\"1960\"\u003eLenovo 2.5\" SFF NVMe Tray Required\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli data-end=\"2037\" data-section-id=\"102llw9\" data-start=\"2001\" style=\"text-align: justify;\"\u003eCommon tray part: \u003cstrong data-end=\"2035\" data-start=\"2021\"\u003eSM17A06246\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli data-end=\"2092\" data-section-id=\"1y9rr97\" data-start=\"2038\" style=\"text-align: justify;\"\u003eRequired for proper fitment in ThinkSystem chassis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2097\" data-start=\"2094\"\u003e\n\u003ch3 data-end=\"2133\" data-section-id=\"i4kj3u\" data-start=\"2099\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2133\" data-start=\"2103\"\u003eImportant Deployment Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2660\" data-start=\"2135\"\u003e\n\t\u003cli data-end=\"2269\" data-section-id=\"zenygc\" data-start=\"2135\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2163\" data-start=\"2137\"\u003eBackplane Requirement:\u003c\/strong\u003e\u003cbr data-end=\"2166\" data-start=\"2163\"\u003e\n\tMust use an AnyBay or NVMe-enabled backplane (SAS\/SATA-only backplanes will NOT support this drive)\u003c\/li\u003e\n\t\u003cli data-end=\"2356\" data-section-id=\"1vmihx\" data-start=\"2271\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2295\" data-start=\"2273\"\u003eU.3 Compatibility:\u003c\/strong\u003e\u003cbr data-end=\"2298\" data-start=\"2295\"\u003e\n\tFully backward compatible with U.2 NVMe infrastructure\u003c\/li\u003e\n\t\u003cli data-end=\"2493\" data-section-id=\"13di6kh\" data-start=\"2358\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2384\" data-start=\"2360\"\u003ePerformance Scaling:\u003c\/strong\u003e\n\t\u003cul data-end=\"2493\" data-start=\"2389\"\u003e\n\t\t\u003cli data-end=\"2437\" data-section-id=\"17fpq32\" data-start=\"2389\"\u003eV2 \/ V3 systems → Full PCIe Gen4 performance\u003c\/li\u003e\n\t\t\u003cli data-end=\"2493\" data-section-id=\"1lx23dk\" data-start=\"2440\"\u003eGen1 systems → Limited to PCIe Gen3 (~3,500 MB\/s)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2660\" data-section-id=\"z5t5il\" data-start=\"2495\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2519\" data-start=\"2497\"\u003eFirmware Behavior:\u003c\/strong\u003e\u003cbr data-end=\"2522\" data-start=\"2519\"\u003e\n\tSystem management (Lenovo XClarity Controller) may display the drive as non-Lenovo firmware, but functionality is typically unaffected\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2665\" data-start=\"2662\"\u003e\n\u003ch3 data-end=\"2684\" data-section-id=\"g4w0aq\" data-start=\"2667\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2684\" data-start=\"2671\"\u003eUse Cases\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2878\" data-start=\"2686\"\u003e\n\t\u003cli data-end=\"2744\" data-section-id=\"n5cwrf\" data-start=\"2686\" style=\"text-align: justify;\"\u003eVirtualization and hyperconverged infrastructure (HCI)\u003c\/li\u003e\n\t\u003cli data-end=\"2790\" data-section-id=\"praak8\" data-start=\"2745\" style=\"text-align: justify;\"\u003eCloud and enterprise storage environments\u003c\/li\u003e\n\t\u003cli data-end=\"2833\" data-section-id=\"1cb617x\" data-start=\"2791\" style=\"text-align: justify;\"\u003eRead-intensive databases and analytics\u003c\/li\u003e\n\t\u003cli data-end=\"2878\" data-section-id=\"pp8c9z\" data-start=\"2834\" style=\"text-align: justify;\"\u003eContent delivery and large-scale storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2883\" data-start=\"2880\"\u003e\n\u003ch3 data-end=\"2900\" data-section-id=\"3l32ru\" data-start=\"2885\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2900\" data-start=\"2889\"\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"3201\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"2902\" style=\"text-align: justify;\"\u003eThe SK Hynix PE8110 3.84TB NVMe SSD provides enterprise-class performance and reliability optimized for read-intensive workloads. When deployed in Lenovo ThinkSystem servers with NVMe backplanes and proper trays, it offers a high-speed, scalable storage solution for modern data center environments.\u003c\/p\u003e\n","brand":"SK Hynix","offers":[{"title":"Default Title","offer_id":55645022158921,"sku":"P55173-003-LENOVO-KIT","price":1614.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/3868\/3209\/files\/b5aa7a53-64e4-5ba8-9866-41d1ab39fbd3.png?v=1776718554","url":"https:\/\/parts.theserverstore.com\/products\/sk-hynix-3-84tb-nvme-u-3-pcie-gen-4-0-x4-ri-sff-2-5-15mm-ssd-pe8110-series-for-lenovo-thinksystem-server-with-tray","provider":"The Server Store Parts","version":"1.0","type":"link"}