{"product_id":"sk-hynix-3-84tb-nvme-u-3-pcie-gen-4-0-x4-ri-2-5-15mm-ssd-pe8110-hfs3t8geetx070n","title":"SK Hynix 3.84TB NVMe U.3 PCIe Gen 4.0 x4 RI 2.5\" 15mm SSD PE8110 HFS3T8GEETX070N","description":"\u003csection data-scroll-anchor=\"false\" data-testid=\"conversation-turn-220\" data-turn=\"assistant\" data-turn-id=\"request-69c2f210-e80c-832f-a3b7-05e7762044c7-13\" dir=\"auto\"\u003e\n\u003ch3 data-end=\"102\" data-section-id=\"f8ux0e\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"102\" data-start=\"4\"\u003eSK Hynix 3.84TB NVMe U.3 PCIe Gen 4.0 x4 Read Intensive 2.5\" 15mm SSD PE8110 (HFS3T8GEETX070N)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"433\" data-start=\"104\" style=\"text-align: justify;\"\u003eThe SK Hynix PE8110 Series 3.84TB NVMe SSD is an enterprise read-intensive drive designed for high-performance data center environments. Built on PCIe Gen4 x4 with NVMe 1.4 and a U.3 interface, it delivers strong throughput, low latency, and efficient power usage for virtualization, cloud workloads, and read-heavy applications.\u003c\/p\u003e\n\n\u003cp data-end=\"552\" data-start=\"435\" style=\"text-align: justify;\"\u003eIt is compatible with a wide range of enterprise servers that support NVMe U.3\/U.2 backplanes and proper drive trays.\u003c\/p\u003e\n\n\u003cp data-end=\"552\" data-start=\"435\" style=\"text-align: justify;\"\u003eNote: With the correct tray, this SSD can fit and operate in any of the listed compatible server platforms, provided the system has an NVMe U.3\/U.2-capable backplane.\u003c\/p\u003e\n\n\u003chr data-end=\"557\" data-start=\"554\"\u003e\n\u003ch2 data-end=\"608\" data-section-id=\"1d8c4e1\" data-start=\"559\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"608\" data-start=\"562\"\u003eServer Compatibility (All Major Platforms)\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ch3 data-end=\"681\" data-section-id=\"1jg3lz\" data-start=\"610\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"681\" data-start=\"614\"\u003eHPE ProLiant Servers (Gen10 Plus \u0026amp; Gen11 – Native Gen4 support)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"885\" data-start=\"682\"\u003e\n\t\u003cli data-end=\"710\" data-section-id=\"19iwh29\" data-start=\"682\" style=\"text-align: justify;\"\u003eDL360 Gen10 Plus \/ Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"739\" data-section-id=\"6kmcmn\" data-start=\"711\" style=\"text-align: justify;\"\u003eDL380 Gen10 Plus \/ Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"768\" data-section-id=\"1b7z7wg\" data-start=\"740\" style=\"text-align: justify;\"\u003eDL325 Gen10 Plus \/ Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"784\" data-section-id=\"112anem\" data-start=\"769\" style=\"text-align: justify;\"\u003eDL345 Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"813\" data-section-id=\"8l40y2\" data-start=\"785\" style=\"text-align: justify;\"\u003eDL385 Gen10 Plus \/ Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"843\" data-section-id=\"1dy22dd\" data-start=\"814\" style=\"text-align: justify;\"\u003eML110 Gen11 \/ ML350 Gen11\u003c\/li\u003e\n\t\u003cli data-end=\"885\" data-section-id=\"1nb3hgi\" data-start=\"844\" style=\"text-align: justify;\"\u003eApollo 4200 \/ 4200 Gen10 Plus \/ Gen11\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"890\" data-start=\"887\"\u003e\n\u003ch3 data-end=\"922\" data-section-id=\"g61dgt\" data-start=\"892\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"922\" data-start=\"896\"\u003eDell PowerEdge Servers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1034\" data-start=\"923\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"979\" data-start=\"923\"\u003eGen17 (PCIe Gen5 \/ Gen4 – Full performance support):\u003c\/strong\u003e\u003cbr data-end=\"982\" data-start=\"979\"\u003e\nR470, R570, R670, R770, R6715, R6725, R7715, R7725\u003c\/p\u003e\n\n\u003cp data-end=\"1161\" data-start=\"1036\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1075\" data-start=\"1036\"\u003eGen16 (PCIe Gen4 – Native support):\u003c\/strong\u003e\u003cbr data-end=\"1078\" data-start=\"1075\"\u003e\nR660, R760, R760xa, R760xs, R760xd2, R6615, R6625, R7615, R7625, R860, R960, T560\u003c\/p\u003e\n\n\u003cp data-end=\"1273\" data-start=\"1163\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1202\" data-start=\"1163\"\u003eGen15 (PCIe Gen4 – Native support):\u003c\/strong\u003e\u003cbr data-end=\"1205\" data-start=\"1202\"\u003e\nR650, R650xs, R6515, R6525, R750, R750xa, R7515, R7525, T550, R550\u003c\/p\u003e\n\n\u003cp data-end=\"1375\" data-start=\"1275\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1323\" data-start=\"1275\"\u003eGen14 (PCIe Gen3 – Drive will be throttled):\u003c\/strong\u003e\u003cbr data-end=\"1326\" data-start=\"1323\"\u003e\nR640, R740, R740xd, R740xd2, R940, R940xa, T640\u003c\/p\u003e\n\n\u003chr data-end=\"1380\" data-start=\"1377\"\u003e\n\u003ch3 data-end=\"1416\" data-section-id=\"1ava0no\" data-start=\"1382\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1416\" data-start=\"1386\"\u003eLenovo ThinkSystem Servers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1531\" data-start=\"1417\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1458\" data-start=\"1417\"\u003eV3 (PCIe Gen5\/Gen4 – Native support):\u003c\/strong\u003e\u003cbr data-end=\"1461\" data-start=\"1458\"\u003e\nSR630 V3, SR650 V3, SR665 V3, SR850 V3, SR860 V3, SR950 V3, ST650 V3\u003c\/p\u003e\n\n\u003cp data-end=\"1652\" data-start=\"1533\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1569\" data-start=\"1533\"\u003eV2 (PCIe Gen4 – Native support):\u003c\/strong\u003e\u003cbr data-end=\"1572\" data-start=\"1569\"\u003e\nSR630 V2, SR650 V2, SR645 V2, SR665 V2, SR850 V2, SR860 V2, ST650 V2, SN550 V2\u003c\/p\u003e\n\n\u003cp data-end=\"1763\" data-start=\"1654\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1697\" data-start=\"1654\"\u003eGen1 (PCIe Gen3 – Performance limited):\u003c\/strong\u003e\u003cbr data-end=\"1700\" data-start=\"1697\"\u003e\nSR630, SR650, SR530, SR550, SR570, SR590, SR850, SR860, SR950\u003c\/p\u003e\n\n\u003chr data-end=\"1768\" data-start=\"1765\"\u003e\n\u003ch3 data-end=\"1795\" data-section-id=\"wzdl6o\" data-start=\"1770\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1795\" data-start=\"1774\"\u003eCisco UCS Servers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1892\" data-start=\"1796\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1844\" data-start=\"1796\"\u003eM7 \/ M8 (PCIe Gen4\/Gen5 – Full performance):\u003c\/strong\u003e\u003cbr data-end=\"1847\" data-start=\"1844\"\u003e\nC220 M7, C240 M7, C225 M7, C245 M7, C240 M8\u003c\/p\u003e\n\n\u003cp data-end=\"1969\" data-start=\"1894\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1930\" data-start=\"1894\"\u003eM6 (PCIe Gen4 – Native support):\u003c\/strong\u003e\u003cbr data-end=\"1933\" data-start=\"1930\"\u003e\nC220 M6, C240 M6, C225 M6, C245 M6\u003c\/p\u003e\n\n\u003cp data-end=\"2044\" data-start=\"1971\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2014\" data-start=\"1971\"\u003eM5 (PCIe Gen3 – Throttled performance):\u003c\/strong\u003e\u003cbr data-end=\"2017\" data-start=\"2014\"\u003e\nC220 M5, C240 M5, C480 M5\u003c\/p\u003e\n\n\u003chr data-end=\"2049\" data-start=\"2046\"\u003e\n\u003ch3 data-end=\"2077\" data-section-id=\"e8308b\" data-start=\"2051\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2077\" data-start=\"2055\"\u003eSupermicro Servers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"2188\" data-start=\"2078\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2124\" data-start=\"2078\"\u003eH13 \/ X13 (PCIe Gen4\/Gen5 – Full support):\u003c\/strong\u003e\u003cbr data-end=\"2127\" data-start=\"2124\"\u003e\nSYS-121H-TNR, SYS-221H-TN24R, SYS-621C-TN12R, AS-2125HS-TNR\u003c\/p\u003e\n\n\u003cp data-end=\"2295\" data-start=\"2190\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2231\" data-start=\"2190\"\u003eH12 \/ X12 (PCIe Gen4 – Full support):\u003c\/strong\u003e\u003cbr data-end=\"2234\" data-start=\"2231\"\u003e\nSYS-120H-TNR, SYS-220H-TN24R, SYS-120C-TN10R, AS-2024US-TNR\u003c\/p\u003e\n\n\u003cp data-end=\"2399\" data-start=\"2297\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2345\" data-start=\"2297\"\u003eH11 \/ X11 (PCIe Gen3 – limited performance):\u003c\/strong\u003e\u003cbr data-end=\"2348\" data-start=\"2345\"\u003e\nSYS-1029U-TN10RT, SYS-2029U-TN24R, AS-1123US-TN9R\u003c\/p\u003e\n\n\u003chr data-end=\"2404\" data-start=\"2401\"\u003e\n\u003ch3 data-end=\"2446\" data-section-id=\"2wvtdx\" data-start=\"2406\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2446\" data-start=\"2410\"\u003eInspur \/ Gigabyte \/ ASUS Servers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2530\" data-start=\"2447\"\u003e\n\t\u003cli data-end=\"2476\" data-section-id=\"oojaqs\" data-start=\"2447\" style=\"text-align: justify;\"\u003eInspur NF5280M6, NF5180M6\u003c\/li\u003e\n\t\u003cli data-end=\"2508\" data-section-id=\"16mo7df\" data-start=\"2477\" style=\"text-align: justify;\"\u003eGigabyte R-Series, G-Series\u003c\/li\u003e\n\t\u003cli data-end=\"2530\" data-section-id=\"z4dfiq\" data-start=\"2509\" style=\"text-align: justify;\"\u003eASUS RS700, RS720\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2535\" data-start=\"2532\"\u003e\n\u003ch2 data-end=\"2559\" data-section-id=\"1izikph\" data-start=\"2537\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2559\" data-start=\"2540\"\u003eTechnical Notes\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cul data-end=\"2870\" data-start=\"2560\"\u003e\n\t\u003cli data-end=\"2638\" data-section-id=\"5engvg\" data-start=\"2560\" style=\"text-align: justify;\"\u003eRequires NVMe U.3 or U.2 backplane (SAS\/SATA backplanes are not supported)\u003c\/li\u003e\n\t\u003cli data-end=\"2701\" data-section-id=\"4c9ep4\" data-start=\"2639\" style=\"text-align: justify;\"\u003eU.3 drives are backward compatible with U.2 infrastructure\u003c\/li\u003e\n\t\u003cli data-end=\"2788\" data-section-id=\"1kr48wa\" data-start=\"2702\" style=\"text-align: justify;\"\u003ePCIe Gen4 systems deliver full performance; Gen3 systems will be bandwidth-limited\u003c\/li\u003e\n\t\u003cli data-end=\"2870\" data-section-id=\"u4vka9\" data-start=\"2789\" style=\"text-align: justify;\"\u003eProper airflow is required for thermal stability in dense server environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2875\" data-start=\"2872\"\u003e\n\u003ch2 data-end=\"2891\" data-section-id=\"ur191l\" data-start=\"2877\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2891\" data-start=\"2880\"\u003eSummary\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cp data-end=\"3122\" data-start=\"2892\" style=\"text-align: justify;\"\u003eThe SK Hynix PE8110 3.84TB NVMe SSD is a versatile enterprise storage solution compatible across Dell, HPE, Lenovo, Cisco, Supermicro, and other major OEM server platforms, provided NVMe-enabled backplanes and trays are installed.\u003c\/p\u003e\n\u003c\/section\u003e\n","brand":"SK Hynix","offers":[{"title":"Default Title","offer_id":55624077606985,"sku":"P55173-003-HYNIX-KIT","price":1614.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/3868\/3209\/files\/6e82df93-1ebc-510a-97c1-8c31c671267c.png?v=1775856172","url":"https:\/\/parts.theserverstore.com\/products\/sk-hynix-3-84tb-nvme-u-3-pcie-gen-4-0-x4-ri-2-5-15mm-ssd-pe8110-hfs3t8geetx070n","provider":"The Server Store Parts","version":"1.0","type":"link"}