{"product_id":"netapp-7-68tb-nvme-u-2-pcie-gen-4-0-x4-ri-sff-2-5-ssd-samsung-pm1733-series-mz-wlj7t60-x4013a-x90-4013a","title":"NetApp 7.68TB NVME U.2 PCIe Gen 4.0 x4 RI SFF 2.5\" SSD Samsung PM1733 Series MZ-WLJ7T60 X4013A X90-4013A","description":"\u003cp data-end=\"105\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"105\" data-start=\"0\"\u003eNetApp 7.68TB NVMe U.2 PCIe Gen4 x4 RI SFF 2.5\" SSD Samsung PM1733 Series MZ-WLJ7T60 X4013A X90-4013A\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp data-end=\"478\" data-start=\"107\" style=\"text-align: justify;\"\u003eThe \u003cstrong data-end=\"142\" data-start=\"111\"\u003eSamsung PM1733 (MZ-WLJ7T60)\u003c\/strong\u003e, branded for NetApp under part number \u003cstrong data-end=\"191\" data-start=\"181\"\u003eX4013A\u003c\/strong\u003e, is a high-performance 7.68TB enterprise NVMe SSD designed for read-intensive (RI) workloads. Built on PCIe Gen4 technology and Samsung’s advanced V-NAND architecture, it delivers exceptional throughput, reliability, and dual-port availability for mission-critical storage environments.\u003c\/p\u003e\n\n\u003chr data-end=\"483\" data-start=\"480\"\u003e\n\u003ch3 data-end=\"513\" data-section-id=\"5cy232\" data-start=\"485\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"513\" data-start=\"489\"\u003eRelated Part Numbers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"577\" data-start=\"514\" style=\"text-align: justify;\"\u003eX4013A, X90-4013A, 108-00858+D0, MZ-WLJ7T60, MZWLJ7T6HALA-00AG5\u003c\/p\u003e\n\n\u003chr data-end=\"582\" data-start=\"579\"\u003e\n\u003ch3 data-end=\"621\" data-section-id=\"1niyif4\" data-start=\"584\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"621\" data-start=\"588\"\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"834\" data-start=\"622\"\u003e\n\t\u003cli data-end=\"646\" data-section-id=\"rgk8h3\" data-start=\"622\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"637\" data-start=\"624\"\u003eCapacity:\u003c\/strong\u003e 7.68TB\u003c\/li\u003e\n\t\u003cli data-end=\"715\" data-section-id=\"16cnmal\" data-start=\"647\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"663\" data-start=\"649\"\u003eInterface:\u003c\/strong\u003e PCIe Gen4 x4 NVMe (backward compatible with Gen3)\u003c\/li\u003e\n\t\u003cli data-end=\"760\" data-section-id=\"1q6zrn\" data-start=\"716\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"734\" data-start=\"718\"\u003eForm Factor:\u003c\/strong\u003e 2.5-inch U.2 (SFF-8639)\u003c\/li\u003e\n\t\u003cli data-end=\"783\" data-section-id=\"j18jxa\" data-start=\"761\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"776\" data-start=\"763\"\u003eZ-Height:\u003c\/strong\u003e 15mm\u003c\/li\u003e\n\t\u003cli data-end=\"834\" data-section-id=\"6onzov\" data-start=\"784\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"800\" data-start=\"786\"\u003eNAND Type:\u003c\/strong\u003e Samsung V6 128-layer TLC V-NAND\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"839\" data-start=\"836\"\u003e\n\u003ch3 data-end=\"860\" data-section-id=\"1lfaz9a\" data-start=\"841\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"860\" data-start=\"845\"\u003ePerformance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1040\" data-start=\"861\"\u003e\n\t\u003cli data-end=\"902\" data-section-id=\"1q0iytr\" data-start=\"861\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"883\" data-start=\"863\"\u003eSequential Read:\u003c\/strong\u003e Up to 7,000 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"945\" data-section-id=\"avezjg\" data-start=\"903\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"926\" data-start=\"905\"\u003eSequential Write:\u003c\/strong\u003e Up to 3,800 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"993\" data-section-id=\"18ujwjw\" data-start=\"946\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"970\" data-start=\"948\"\u003eRandom Read (4KB):\u003c\/strong\u003e Up to 1,450,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1040\" data-section-id=\"4b22l4\" data-start=\"994\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1019\" data-start=\"996\"\u003eRandom Write (4KB):\u003c\/strong\u003e Up to 135,000 IOPS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1045\" data-start=\"1042\"\u003e\n\u003ch3 data-end=\"1078\" data-section-id=\"zqh55d\" data-start=\"1047\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1078\" data-start=\"1051\"\u003eEndurance \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1326\" data-start=\"1079\"\u003e\n\t\u003cli data-end=\"1121\" data-section-id=\"12otf6c\" data-start=\"1079\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1099\" data-start=\"1081\"\u003eWorkload Type:\u003c\/strong\u003e Read Intensive (RI)\u003c\/li\u003e\n\t\u003cli data-end=\"1181\" data-section-id=\"66ho3g\" data-start=\"1122\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1138\" data-start=\"1124\"\u003eEndurance:\u003c\/strong\u003e 1 DWPD (Drive Write Per Day for 5 years)\u003c\/li\u003e\n\t\u003cli data-end=\"1249\" data-section-id=\"17xm2i6\" data-start=\"1182\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1208\" data-start=\"1184\"\u003eEnterprise Features:\u003c\/strong\u003e Designed for 24\/7 continuous operation\u003c\/li\u003e\n\t\u003cli data-end=\"1326\" data-section-id=\"1y8uzis\" data-start=\"1250\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1276\" data-start=\"1252\"\u003eFail-in-Place (FIP):\u003c\/strong\u003e Maintains operation even with NAND cell failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1331\" data-start=\"1328\"\u003e\n\u003ch3 data-end=\"1358\" data-section-id=\"1ihbvzw\" data-start=\"1333\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1358\" data-start=\"1337\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1399\" data-start=\"1359\"\u003e\n\t\u003cli data-end=\"1379\" data-section-id=\"17sb251\" data-start=\"1359\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1372\" data-start=\"1361\"\u003eActive:\u003c\/strong\u003e ~20W\u003c\/li\u003e\n\t\u003cli data-end=\"1399\" data-section-id=\"17mluzg\" data-start=\"1380\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1391\" data-start=\"1382\"\u003eIdle:\u003c\/strong\u003e ~8.5W\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1404\" data-start=\"1401\"\u003e\n\u003ch3 data-end=\"1426\" data-section-id=\"pm8yra\" data-start=\"1406\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1426\" data-start=\"1410\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1910\" data-start=\"1427\"\u003e\n\t\u003cli data-end=\"1576\" data-section-id=\"ynxpkx\" data-start=\"1427\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1456\" data-start=\"1429\"\u003eDual-Port NVMe Support:\u003c\/strong\u003e\u003cbr data-end=\"1459\" data-start=\"1456\"\u003e\n\tEnables high-availability (HA) configurations—critical for enterprise storage arrays where redundancy is required\u003c\/li\u003e\n\t\u003cli data-end=\"1705\" data-section-id=\"fsq2f8\" data-start=\"1578\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1614\" data-start=\"1580\"\u003eSR-IOV Virtualization Support:\u003c\/strong\u003e\u003cbr data-end=\"1617\" data-start=\"1614\"\u003e\n\tSupports up to 64 virtual functions for scalable cloud and multi-tenant environments\u003c\/li\u003e\n\t\u003cli data-end=\"1813\" data-section-id=\"11ib14d\" data-start=\"1707\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1746\" data-start=\"1709\"\u003eHigh Throughput Gen4 Performance:\u003c\/strong\u003e\u003cbr data-end=\"1749\" data-start=\"1746\"\u003e\n\tSignificantly faster than previous-generation PCIe Gen3 SSDs\u003c\/li\u003e\n\t\u003cli data-end=\"1910\" data-section-id=\"1wdnryz\" data-start=\"1815\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1847\" data-start=\"1817\"\u003eEnterprise Data Integrity:\u003c\/strong\u003e\u003cbr data-end=\"1850\" data-start=\"1847\"\u003e\n\tAdvanced error correction and firmware-level protections\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1915\" data-start=\"1912\"\u003e\n\u003ch3 data-end=\"1938\" data-section-id=\"n07754\" data-start=\"1917\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1938\" data-start=\"1921\"\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2198\" data-start=\"1939\"\u003e\n\t\u003cli data-end=\"2012\" data-section-id=\"it4bo6\" data-start=\"1939\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1959\" data-start=\"1941\"\u003ePlatform Type:\u003c\/strong\u003e Enterprise storage arrays and NVMe-enabled servers\u003c\/li\u003e\n\t\u003cli data-end=\"2088\" data-section-id=\"1n7rfrd\" data-start=\"2013\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2041\" data-start=\"2015\"\u003eInterface Requirement:\u003c\/strong\u003e U.2 NVMe backplane or PCIe Gen4 NVMe support\u003c\/li\u003e\n\t\u003cli data-end=\"2198\" data-section-id=\"1xnn1cl\" data-start=\"2089\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2104\" data-start=\"2091\"\u003eUse Case:\u003c\/strong\u003e NetApp storage systems and other enterprise infrastructures requiring dual-port NVMe drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2203\" data-start=\"2200\"\u003e\n\u003ch3 data-end=\"2228\" data-section-id=\"1ws83tv\" data-start=\"2205\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2228\" data-start=\"2209\"\u003eImportant Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2499\" data-start=\"2229\"\u003e\n\t\u003cli data-end=\"2313\" data-section-id=\"1syijns\" data-start=\"2229\" style=\"text-align: justify;\"\u003eThis is a \u003cstrong data-end=\"2268\" data-start=\"2241\"\u003eU.2 (SFF-8639) NVMe SSD\u003c\/strong\u003e, not compatible with SAS\/SATA-only systems\u003c\/li\u003e\n\t\u003cli data-end=\"2419\" data-section-id=\"k8lp2m\" data-start=\"2314\" style=\"text-align: justify;\"\u003eDual-port functionality is typically utilized in \u003cstrong data-end=\"2394\" data-start=\"2365\"\u003eenterprise storage arrays\u003c\/strong\u003e (e.g., NetApp systems)\u003c\/li\u003e\n\t\u003cli data-end=\"2499\" data-section-id=\"1ugx2av\" data-start=\"2420\" style=\"text-align: justify;\"\u003eEnsure system firmware and backplane support NVMe Gen4 for full performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2504\" data-start=\"2501\"\u003e\n\u003ch3 data-end=\"2521\" data-section-id=\"3l32ru\" data-start=\"2506\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2521\" data-start=\"2510\"\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"2854\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"2522\" style=\"text-align: justify;\"\u003eThe \u003cstrong data-end=\"2576\" data-start=\"2526\"\u003eNetApp X4013A \/ Samsung PM1733 7.68TB NVMe SSD\u003c\/strong\u003e is a powerful enterprise storage solution offering ultra-fast PCIe Gen4 performance, dual-port reliability, and robust endurance. It is ideal for high-availability storage systems, cloud infrastructure, and data-intensive applications where performance and uptime are critical.\u003c\/p\u003e\n","brand":"NetApp","offers":[{"title":"Default Title","offer_id":55647243239497,"sku":"X90-4013A-PM1733","price":1899.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/3868\/3209\/files\/2819fec6-8597-5182-9f3d-153a08df6ebc.png?v=1776807076","url":"https:\/\/parts.theserverstore.com\/products\/netapp-7-68tb-nvme-u-2-pcie-gen-4-0-x4-ri-sff-2-5-ssd-samsung-pm1733-series-mz-wlj7t60-x4013a-x90-4013a","provider":"The Server Store Parts","version":"1.0","type":"link"}