{"product_id":"intel-15-36tb-nvme-u-2-pcie-gen3-0-x4-ri-2-5-ssd-d5-p4326-series-lenovo-thinksystem-server-ssdpe2nv153t8","title":"Intel 15.36TB NVMe U.2 PCIe Gen3.0 x4 RI 2.5\" SSD D5-P4326 Series Lenovo ThinkSystem Server SSDPE2NV153T8","description":"\u003cp data-end=\"130\" data-start=\"0\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"130\" data-start=\"0\"\u003eIntel 15.36TB NVMe U.2 PCIe Gen3.0 x4 Read Intensive (RI) 2.5\" SSD D5-P4326 Series SSDPE2NV153T8 for Lenovo ThinkSystem Server\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp data-end=\"498\" data-start=\"132\" style=\"text-align: justify;\"\u003eThe Intel D5-P4326 Series (Model: SSDPE2NV153T8) is a high-capacity, enterprise-grade NVMe solid-state drive designed for read-intensive workloads. Built with 64-layer QLC 3D NAND, it provides excellent storage density and efficiency in a 2.5-inch U.2 (SFF-8639) form factor, making it a strong fit for Lenovo ThinkSystem and ThinkServer platforms with NVMe support.\u003c\/p\u003e\n\n\u003chr data-end=\"503\" data-start=\"500\"\u003e\n\u003ch3 data-end=\"533\" data-section-id=\"5cy232\" data-start=\"505\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"533\" data-start=\"509\"\u003eRelated Part Numbers\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"590\" data-start=\"534\" style=\"text-align: justify;\"\u003eSSDPE2NV153T8, SSDPE2NV153T801, J67810-075, 73-0004-01\u003c\/p\u003e\n\n\u003cp data-end=\"626\" data-start=\"592\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"611\" data-start=\"592\"\u003eLenovo Tray PN:\u003c\/strong\u003e\u003cbr data-end=\"614\" data-start=\"611\"\u003e\nSM17A06246\u003c\/p\u003e\n\n\u003chr data-end=\"631\" data-start=\"628\"\u003e\n\u003ch3 data-end=\"669\" data-section-id=\"189wkz0\" data-start=\"633\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"669\" data-start=\"637\"\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1049\" data-start=\"670\"\u003e\n\t\u003cli data-end=\"695\" data-section-id=\"1cxgu2n\" data-start=\"670\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"685\" data-start=\"672\"\u003eCapacity:\u003c\/strong\u003e 15.36TB\u003c\/li\u003e\n\t\u003cli data-end=\"733\" data-section-id=\"z6ko3c\" data-start=\"696\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"712\" data-start=\"698\"\u003eInterface:\u003c\/strong\u003e PCIe 3.0 x4 (NVMe)\u003c\/li\u003e\n\t\u003cli data-end=\"780\" data-section-id=\"zsmbw8\" data-start=\"734\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"752\" data-start=\"736\"\u003eForm Factor:\u003c\/strong\u003e 2.5\" U.2 (SFF-8639), 15mm\u003c\/li\u003e\n\t\u003cli data-end=\"820\" data-section-id=\"136qetr\" data-start=\"781\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"797\" data-start=\"783\"\u003eNAND Type:\u003c\/strong\u003e 64-Layer QLC 3D NAND\u003c\/li\u003e\n\t\u003cli data-end=\"862\" data-section-id=\"1799ekp\" data-start=\"821\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"843\" data-start=\"823\"\u003eSequential Read:\u003c\/strong\u003e Up to 3,200 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"905\" data-section-id=\"1n1n140\" data-start=\"863\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"886\" data-start=\"865\"\u003eSequential Write:\u003c\/strong\u003e Up to 1,600 MB\/s\u003c\/li\u003e\n\t\u003cli data-end=\"951\" data-section-id=\"1b7a50d\" data-start=\"906\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"930\" data-start=\"908\"\u003eRandom Read (4KB):\u003c\/strong\u003e Up to 580,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"991\" data-section-id=\"ddmj4n\" data-start=\"952\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"971\" data-start=\"954\"\u003eRandom Write:\u003c\/strong\u003e Up to 15,000 IOPS\u003c\/li\u003e\n\t\u003cli data-end=\"1020\" data-section-id=\"15qrwrd\" data-start=\"992\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1011\" data-start=\"994\"\u003eRead Latency:\u003c\/strong\u003e 135 µs\u003c\/li\u003e\n\t\u003cli data-end=\"1049\" data-section-id=\"19trbd3\" data-start=\"1021\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1041\" data-start=\"1023\"\u003eWrite Latency:\u003c\/strong\u003e 60 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1054\" data-start=\"1051\"\u003e\n\u003ch3 data-end=\"1087\" data-section-id=\"16vvq8h\" data-start=\"1056\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1087\" data-start=\"1060\"\u003eReliability \u0026amp; Endurance\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1299\" data-start=\"1088\"\u003e\n\t\u003cli data-end=\"1167\" data-section-id=\"vpyp6\" data-start=\"1088\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1104\" data-start=\"1090\"\u003eEndurance:\u003c\/strong\u003e\n\n\t\u003cul data-end=\"1167\" data-start=\"1109\"\u003e\n\t\t\u003cli data-end=\"1140\" data-section-id=\"sth085\" data-start=\"1109\"\u003eUp to 24.6 PBW (Sequential)\u003c\/li\u003e\n\t\t\u003cli data-end=\"1167\" data-section-id=\"yzj78c\" data-start=\"1143\"\u003eUp to 5 PBW (Random)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1197\" data-section-id=\"dudf1e\" data-start=\"1168\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1179\" data-start=\"1170\"\u003eMTBF:\u003c\/strong\u003e 2 million hours\u003c\/li\u003e\n\t\u003cli data-end=\"1247\" data-section-id=\"1xqnli0\" data-start=\"1198\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1226\" data-start=\"1200\"\u003ePower Loss Protection:\u003c\/strong\u003e Yes (Enhanced PLI)\u003c\/li\u003e\n\t\u003cli data-end=\"1299\" data-section-id=\"v16uix\" data-start=\"1248\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1270\" data-start=\"1250\"\u003eData Protection:\u003c\/strong\u003e End-to-End Data Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1304\" data-start=\"1301\"\u003e\n\u003ch3 data-end=\"1335\" data-section-id=\"qquco7\" data-start=\"1306\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1335\" data-start=\"1310\"\u003ePower \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"1429\" data-start=\"1336\"\u003e\n\t\u003cli data-end=\"1362\" data-section-id=\"1km2ctm\" data-start=\"1336\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1355\" data-start=\"1338\"\u003eActive Power:\u003c\/strong\u003e ~20W\u003c\/li\u003e\n\t\u003cli data-end=\"1386\" data-section-id=\"qaya1h\" data-start=\"1363\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1380\" data-start=\"1365\"\u003eIdle Power:\u003c\/strong\u003e ~5W\u003c\/li\u003e\n\t\u003cli data-end=\"1429\" data-section-id=\"10q3ptb\" data-start=\"1387\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1415\" data-start=\"1389\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1434\" data-start=\"1431\"\u003e\n\u003ch3 data-end=\"1476\" data-section-id=\"1wrnuto\" data-start=\"1436\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1476\" data-start=\"1440\"\u003eLenovo ThinkSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"1629\" data-start=\"1478\" style=\"text-align: justify;\"\u003eThis SSD is compatible with Lenovo systems that support \u003cstrong data-end=\"1566\" data-start=\"1534\"\u003eU.2 NVMe drives over PCIe x4\u003c\/strong\u003e and are configured with \u003cstrong data-end=\"1628\" data-start=\"1591\"\u003eAnyBay or NVMe-enabled backplanes\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch4 data-end=\"1665\" data-start=\"1631\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1665\" data-start=\"1636\"\u003eRack Servers (Mainstream)\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"1944\" data-start=\"1666\"\u003e\n\t\u003cli data-end=\"1754\" data-section-id=\"8dcmpu\" data-start=\"1666\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1699\" data-start=\"1668\"\u003eSR650 \/ SR650 V2 \/ SR650 V3\u003c\/strong\u003e\n\n\t\u003cul data-end=\"1754\" data-start=\"1702\"\u003e\n\t\t\u003cli data-end=\"1754\" data-section-id=\"95mg8m\" data-start=\"1702\"\u003eUp to 24 NVMe drives in NVMe-rich configurations\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1846\" data-section-id=\"1lqzeej\" data-start=\"1756\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1789\" data-start=\"1758\"\u003eSR630 \/ SR630 V2 \/ SR630 V3\u003c\/strong\u003e\n\t\u003cul data-end=\"1846\" data-start=\"1792\"\u003e\n\t\t\u003cli data-end=\"1846\" data-section-id=\"hm6zo9\" data-start=\"1792\"\u003eMultiple NVMe drives supported via NVMe backplanes\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"1944\" data-section-id=\"1lfnntf\" data-start=\"1848\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"1880\" data-start=\"1850\"\u003eSR530, SR550, SR570, SR590\u003c\/strong\u003e\n\t\u003cul data-end=\"1944\" data-start=\"1883\"\u003e\n\t\t\u003cli data-end=\"1944\" data-section-id=\"r5qyj4\" data-start=\"1883\"\u003eSupported with 8-bay or 10-bay AnyBay\/NVMe configurations\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"1949\" data-start=\"1946\"\u003e\n\u003ch4 data-end=\"1991\" data-start=\"1951\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"1991\" data-start=\"1956\"\u003eMission-Critical \u0026amp; High-Density\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"2241\" data-start=\"1992\"\u003e\n\t\u003cli data-end=\"2082\" data-section-id=\"fhc2gp\" data-start=\"1992\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2025\" data-start=\"1994\"\u003eSR850 \/ SR850 V2 \/ SR850 V3\u003c\/strong\u003e\n\n\t\u003cul data-end=\"2082\" data-start=\"2028\"\u003e\n\t\t\u003cli data-end=\"2082\" data-section-id=\"1sl2r7n\" data-start=\"2028\"\u003eHigh-density 4-socket systems with NVMe front bays\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2162\" data-section-id=\"1xuyejg\" data-start=\"2084\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2095\" data-start=\"2086\"\u003eSR950\u003c\/strong\u003e\n\t\u003cul data-end=\"2162\" data-start=\"2098\"\u003e\n\t\t\u003cli data-end=\"2162\" data-section-id=\"15rc2di\" data-start=\"2098\"\u003eSupports up to 12 NVMe drives in storage-rich configurations\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\t\u003cli data-end=\"2241\" data-section-id=\"14lwi8w\" data-start=\"2164\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2190\" data-start=\"2166\"\u003eSD530 (D2 Enclosure)\u003c\/strong\u003e\n\t\u003cul data-end=\"2241\" data-start=\"2193\"\u003e\n\t\t\u003cli data-end=\"2241\" data-section-id=\"5sb88b\" data-start=\"2193\"\u003eModular nodes supporting NVMe configurations\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2246\" data-start=\"2243\"\u003e\n\u003ch4 data-end=\"2270\" data-start=\"2248\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2270\" data-start=\"2253\"\u003eTower Servers\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"2368\" data-start=\"2271\"\u003e\n\t\u003cli data-end=\"2368\" data-section-id=\"1jaj99c\" data-start=\"2271\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2304\" data-start=\"2273\"\u003eST550 \/ ST650 V2 \/ ST650 V3\u003c\/strong\u003e\n\n\t\u003cul data-end=\"2368\" data-start=\"2307\"\u003e\n\t\t\u003cli data-end=\"2368\" data-section-id=\"1ljob0x\" data-start=\"2307\"\u003eSupports NVMe storage for enterprise and edge deployments\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2373\" data-start=\"2370\"\u003e\n\u003ch4 data-end=\"2404\" data-start=\"2375\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2404\" data-start=\"2380\"\u003eBlade \u0026amp; Edge Systems\u003c\/strong\u003e\u003c\/h4\u003e\n\n\u003cul data-end=\"2482\" data-start=\"2405\"\u003e\n\t\u003cli data-end=\"2482\" data-section-id=\"akh4qq\" data-start=\"2405\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2424\" data-start=\"2407\"\u003eSN550 \/ SN850\u003c\/strong\u003e\n\n\t\u003cul data-end=\"2482\" data-start=\"2427\"\u003e\n\t\t\u003cli data-end=\"2482\" data-section-id=\"11bhxgn\" data-start=\"2427\"\u003eRequires mezzanine storage modules for NVMe support\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2487\" data-start=\"2484\"\u003e\n\u003ch3 data-end=\"2525\" data-section-id=\"gfle5y\" data-start=\"2489\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2525\" data-start=\"2493\"\u003eSupported NVMe Tray (Lenovo)\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2655\" data-start=\"2526\"\u003e\n\t\u003cli data-end=\"2655\" data-section-id=\"12cwilb\" data-start=\"2526\" style=\"text-align: justify;\"\u003e\n\u003cstrong data-end=\"2542\" data-start=\"2528\"\u003eSM17A06246\u003c\/strong\u003e\n\n\t\u003cul data-end=\"2655\" data-start=\"2545\"\u003e\n\t\t\u003cli data-end=\"2585\" data-section-id=\"1lyeb4j\" data-start=\"2545\"\u003eStandard 2.5-inch NVMe\/SAS\/SATA tray\u003c\/li\u003e\n\t\t\u003cli data-end=\"2655\" data-section-id=\"p1g163\" data-start=\"2588\"\u003eCompatible with most ThinkSystem platforms (SR650, SR630, etc.)\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2660\" data-start=\"2657\"\u003e\n\u003ch3 data-end=\"2685\" data-section-id=\"1ws83tv\" data-start=\"2662\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"2685\" data-start=\"2666\"\u003eImportant Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul data-end=\"2972\" data-start=\"2686\"\u003e\n\t\u003cli data-end=\"2749\" data-section-id=\"fe7wya\" data-start=\"2686\" style=\"text-align: justify;\"\u003eRequires \u003cstrong data-end=\"2747\" data-start=\"2697\"\u003eNVMe-enabled backplane or AnyBay configuration\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli data-end=\"2817\" data-section-id=\"i63ceg\" data-start=\"2750\" style=\"text-align: justify;\"\u003eStandard SAS\/SATA-only backplanes will NOT recognize this drive\u003c\/li\u003e\n\t\u003cli data-end=\"2903\" data-section-id=\"1qj78cc\" data-start=\"2818\" style=\"text-align: justify;\"\u003eNVMe enablement kits or switch adapters may be required if not factory configured\u003c\/li\u003e\n\t\u003cli data-end=\"2972\" data-section-id=\"qsxw3j\" data-start=\"2904\" style=\"text-align: justify;\"\u003eCompatible with PCIe Gen4\/Gen5 systems (operates at Gen3 speeds)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"2977\" data-start=\"2974\"\u003e\n\u003ch3 data-end=\"3007\" data-section-id=\"1vhturc\" data-start=\"2979\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3007\" data-start=\"2983\"\u003eWorkload Suitability\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"3065\" data-start=\"3008\" style=\"text-align: justify;\"\u003eOptimized for \u003cstrong data-end=\"3053\" data-start=\"3022\"\u003eread-intensive applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\n\u003cul data-end=\"3178\" data-start=\"3066\"\u003e\n\t\u003cli data-end=\"3094\" data-section-id=\"18fpe2d\" data-start=\"3066\" style=\"text-align: justify;\"\u003eData lakes and analytics\u003c\/li\u003e\n\t\u003cli data-end=\"3130\" data-section-id=\"ytanrs\" data-start=\"3095\" style=\"text-align: justify;\"\u003eContent delivery networks (CDN)\u003c\/li\u003e\n\t\u003cli data-end=\"3153\" data-section-id=\"ncq6ap\" data-start=\"3131\" style=\"text-align: justify;\"\u003eWarm storage tiers\u003c\/li\u003e\n\t\u003cli data-end=\"3178\" data-section-id=\"bwfbvm\" data-start=\"3154\" style=\"text-align: justify;\"\u003eRead-heavy databases\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr data-end=\"3183\" data-start=\"3180\"\u003e\n\u003ch3 data-end=\"3200\" data-section-id=\"3l32ru\" data-start=\"3185\" style=\"text-align: justify;\"\u003e\u003cstrong data-end=\"3200\" data-start=\"3189\"\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp data-end=\"3492\" data-is-last-node=\"\" data-is-only-node=\"\" data-start=\"3201\" style=\"text-align: justify;\"\u003eThe Intel D5-P4326 15.36TB NVMe SSD (SSDPE2NV153T8) is a high-density, cost-effective storage solution for Lenovo ThinkSystem environments. When deployed with the proper NVMe backplane and SM17A06246 tray, it delivers reliable performance and scalability for enterprise read-heavy workloads.\u003c\/p\u003e\n","brand":"Intel","offers":[{"title":"Default Title","offer_id":55652345741385,"sku":"SSDPE2NV153T8-LENOVO-KIT","price":3799.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0638\/3868\/3209\/files\/be0e5246-fce6-539a-af11-7c27412493f2.png?v=1776971763","url":"https:\/\/parts.theserverstore.com\/products\/intel-15-36tb-nvme-u-2-pcie-gen3-0-x4-ri-2-5-ssd-d5-p4326-series-lenovo-thinksystem-server-ssdpe2nv153t8","provider":"The Server Store Parts","version":"1.0","type":"link"}